Introducing the Sharp600 Pure Sine Wave UPS Series, ranging from 500 VA to 3000 VA. It ensures stable power with pure sine wave technology and features like boost/buck AVR, auto-sensing frequency, and intelligent battery management. Customize settings, enable ECO mode, and benefit from no-load shutdown for efficiency. Stay informed via the alarm system and power-on self-test. Enjoy seamless power restoration with cold start and auto-restart. Safety is paramount with short circuit/overload protection. Communicate effortlessly via USB, RJ45, and optional SNMP ports. Elevate your power backup with Sharp600's reliability, intelligence, and efficiency.
Get Your Quote Now! Download the PDF here
Sharp600 500 VA – 3000 VA:
- Pure sine wave output
- DSP digital control
- Boost and buck AVR for voltage stabilization
- Auto sensing frequency
- Adjustable charging current and battery shutdown point
- Settable ECO mode and no-load shutdown
- Humanized alarm system
- Power-on self test
- Cold start
- Auto restart when mains power is restored
- Intelligent battery management
- Short circuit and overload protection
- Automatic charging in OFF mode
- USB & RJ45, AS400 / SNMP (optional) communication port
MODEL | SHARP605 | SHARP610 | SHARP615 | SHARP620 | SHARP630 | |
Capacity | 500 VA / 300 W | 1000 VA / 800 W | 1500 VA / 1200 W | 2000 VA / 1600 W | 3000 VA / 2400 W | |
DC INPUT | ||||||
Rated voltage | 12 V | 24 V | 36 V (S) 48 V (H) |
48 V | ||
DC input range (default) | 10 ~ 15 V | 20 ~ 30 V | 30 ~ 45 V (S) 40 ~ 60 V (H) |
40 ~ 60 V | ||
AC INPUT | ||||||
AC input range (bypass mode) |
0 ~ 121 / 132 / 138 / 144 Vac for 100 / 110 / 115 / 120 Vac ± 10 Vac 0 ~ 242 / 264 / 276 / 288 Vac for 200 / 220 / 230 / 240 Vac ± 10 Vac |
|||||
AC input range (mains mode) | 100 V: 70 ~ 130 Vac 110 V: 80 ~ 140 Vac 115 V: 85 ~ 145 Vac 120 V: 90 ~ 150 Vac 200 V: 145 ~ 260 Vac 220 V: 165 ~ 280 Vac 230 V: 175 ~ 290 Vac 240 V: 185 ~ 300 Vac |
|||||
Frequency input range | 50 Hz / 60 Hz (auto-sense), 50 Hz / 60 Hz ± 5% ~ 15% | |||||
Generator connection | Available (generator input power is settable) | |||||
OUTPUT | ||||||
Inverter output range | 100 / 110 / 115 / 120 / 200 / 220 / 230 / 240 Vac ± 5% (settable) | |||||
AC output range (bypass mode) |
0 ~ 121 / 132 / 138 / 144 Vac for 100 / 110 / 115 / 120 Vac ± 10 Vac 0 ~ 242 / 264 / 276 / 288 Vac for 200 / 220 / 230 V / 240 Vac ± 10 Vac
|
|||||
AC output range (mains mode) | 100 V: 90 ~ 110 Vac 110 V: 99 ~ 121 Vac 115 V: 103 ~126 Vac 120 V: 108 ~132 Vac 200 V: 166 ~226 Vac 220 V: 188 ~245 Vac, 230 V: 199 ~ 254 Vac 240 V: 210 ~ 264 Vac |
|||||
Output frequency | 50 / 60 Hz ± 0.3 Hz (settable) | |||||
Waveform | Pure sine wave | |||||
Inverter efficiency | Max. 75% | Max. 80% | Max. 85% | |||
Energy saving mode | Settable (< 3% load) , enter in 80 s | |||||
No-load shutdown | Settable (< 3% load), shut down in 80 s | |||||
Transfer time | ≤ 10 ms | |||||
THDV (resistive load) |
≤ 5% | |||||
Protections | Overload, short circuit (inverter), battery low voltage, battery overcharge, overtemperature | |||||
Overload (mains mode) | 110% for 120 s, 125% for 60 s, 150% for 10 s (transfer to bypass mode) | |||||
Overload (inverter mode) | 110% for 60 s, 125% for 10 s, 150% for 5 s (shut down directly) | |||||
Mute | Automatic mute in 60 s or by manual | |||||
BATTERIES | ||||||
Inbuilt battery (standard model) | / | 12 V / 7 Ah x 2 | 12 V / 9 Ah x 2 | 12 V / 9 Ah x 3 | 12 V / 9 Ah x 4 | |
Charging current | Standard model (S): 1 A (default) | |||||
Long time model (H): 10 A (default); < 10 A, set step 1 A; ≥ 10 A, set step 5 A | ||||||
Max. 10 A (H) | Max. 15 A (H) | / | Max. 20 A (H) | Max. 25 A (H) | ||
Equalizing charge voltage |
Single battery 14.1 Vdc (default), 13.6 ~ 15 Vdc adjustable | |||||
Floating charge voltage | Single battery 13.5 Vdc (default),13.2 ~ 14.6 Vdc adjustable | |||||
Low voltage alarm point | Single battery 10.8 Vdc (default), 9.6 ~ 13 Vdc adjustable | |||||
Low voltage shutdown point | Single battery 10.2 Vdc (default), 9.6 ~ 11.5 Vdc adjustable | |||||
OTHERS | ||||||
Communications | USB & RJ45 (standard), dry contacts / SNMP (optional) | |||||
Operating temperature | 5℃ ~ 40℃ | |||||
Operating humidity | Relative humidity ≤ 93% | |||||
Noise level | ≤ 50 dB (1 m) | |||||
Tower | Dimensions (W × D × H) (mm) | 144 x 345 x 215 (S / H) | 144 x 410 x 215 (S) 144 x 345 x 215 (H) |
157.5 x 460x 221.5(S) 190 x 467 x 335.5 (H) |
||
Packaged dimensions (W × D × H) (mm) | 236 x 427 x 316 (S / H) | 236 x 492 x 316 (S) 236 x 427 x 316 (H) |
238 x 550 x 305 (S) 320 x 592 x 462 (H) |
|||
Net weight (kg) | 7.0 (H) | 12.2 (S) 11.6 (H) |
14.2 (S) | 18.5 (S) 17.8 (H) |
23.6(S) 28.0 (H) |
|
Gross weight (kg) | 8.0 (H) | 13.2 (S) 12.6 (H) |
15.2 (S) | 19.8 (S) 18.8 (H) |
25 (S) 30.0 (H) |
|
Rack mount | Dimensions (W × D × H) (mm) | — | 440 × 338 × 88 (S) | 440 × 410 × 132 (S) | ||
Packaged dimensions (W × D × H) (mm) | — | 611 × 448 × 208 (S) | 611 × 505 × 235 (S) | |||
Net weight (kg) | — | 14.6 (S) | 17.2 (S) | 21.3 (S) | 26.7 (S) | |
Gross weight (kg) | — | 16.8 (S) | 20.4 (S) | 24.5 (S) | 30.5 (S) |